EMC

Article: Benefits of VSDs

Salt Lake City (Head Quarters)   801  366.4100   or   800  433.4548   -    Denver  303  574.9448    -    Boise   208  573.1038
Benefits of VSDs

Table of Contents

  • Energy Savings with Variable Speed Drives
  • Variable Torque vs. Constant Torque
  • Why Variable Torque Loads Offer Great Energy Savings
  • Energy Consumption
  • Tighter Process Control with Variable Speed Drives
  • Extended Equipment Life and Reduced Maintenance
  • Problems Caused by Full-Voltage (Across The Line) Starters
  • Energy Savings with Variable Speed Dives

    If you have an AC motor-driven application that does not need to be run at full speed, then you can cut down energy costs by controlling the motor with a variable speed drive (VSD, aka variable frequency drive). Variable speed drives allow you to match the speed of the motor-driven equipment to the process requirement. There is no other method of AC motor control that allows you to accomplish this.

    Example of an Excellent Variable Speed Drive Candidate*
    Excellent Benefits

    Example of a Decent Variable Speed Drive Candidate*
    Decent Benefits

    Example of a Poor Variable Speed Drive*
    Poor Benefits

    Variable Torque vs. Constant Torque

    Variable speed drives, and the loads they are applied to, can generally be divided into two groups: constant torque and variable torque. The energy savings potential of variable torque applications is much greater than that of constant torque applications. Variable torque loads include centrifugal pumps and fans, which make up the majority of HVAC applications. Constant torque loads include vibrating conveyors, punch presses, rock crushers, machine tools, and other applications where the drive follows a constant V/Hz ratio.
     

    Why Variable Torque Loads Offer Great Energy Savings

    In variable torque applications, the torque required varies with the square of the speed, and the horsepower required varies with the cube of the speed, resulting in a large reduction of horsepower for even a small reduction in speed. The motor will consume only 25% as much energy at 50% speed than it will at 100% speed. This is referred to as the Affinity Laws, which define the relationships between speed, flow, torque, and horsepower. The following diagram illustrates these relationships:

    Benefits Affinity

    Energy Consumption

    As the table below shows, variable speed drives (VSDs) allow you to consume less energy than other speed control techniques when load requirements are less than full speed, as is usually the case in HVAC applications.

    Typical Energy Consumption of a Centrifugal Fan System Using Selected
    Speed Control Techniques

    Benefits of Energy Consumption

    Tighter Process Control with Variable Speed Drives

    No other AC motor control method compares to variable speed drives when it comes to accurate process control. Full-voltage (across the line) starters can only run the motor at full speed, and soft starts and reduced voltage soft starters can only gradually ramp the motor up to full speed, and back down to shutdown. Variable speed drives, on the other hand, can be programmed to run the motor at a precise speed, to stop at a precise position, or to apply a specific amount of torque.

    In fact, modern AC variable speed drives are very close to the DC drive in terms of fast torque response and speed accuracy. However, AC motors are much more reliable and affordable than DC motors, making them far more prevalent.

    Most drives used in the field utilize Voltz/Hertz type control, which means they provide open-loop operation. These drives are unable to retrieve feedback from the process, but are sufficient for the majority of variable speed drive applications. Many open-loop variable speed drives do offer slip compensation though, which enables the drive to measure its output current and estimate the difference in actual speed and the setpoint (the programmed input value). The drive will then automatically adjust itself towards the setpoint based on this estimation.

    Most variable torque drives have PID capability for fan and pump applications, which allows the drive to hold the setpoint based on actual feedback from the process, rather than relying on an estimation. A transducer or transmitter is used to detect process variables such as pressure levels, liquid flow rate, air flow rate, or liquid level. Then the signal is sent to a PLC, which communicates the feedback from the process to the drive. The variable speed drive uses this continual feedback to adjust itself to hold the setpoint.

    High levels of accuracy for other applications can also be achieved through drives that offer closed-loop operation. Closed-loop operation can be accomplished with either a field-oriented vector drive, or a sensorless vector drive. The field-oriented vector drive obtains process feedback from an encoder, which measures and transmits to the drive the speed and/or rate of the process, such as a conveyor, machine tool, or extruder. The drive then adjusts itself accordingly to sustain the programmed speed, rate, torque, and/or position.

    Extended Equipment Life and Reduced Maintenance

    Single-speed starting methods start motors abruptly, subjecting the motor to a high starting torque and to current surges that are up to 10 times the full-load current. Variable speed drives, on the other hand, gradually ramp the motor up to operating speed to lessen mechanical and electrical stress, reducing maintenance and repair costs, and extending the life of the motor and the driven equipment.

    Soft starts, or reduced-voltage soft starters (RVSS), are also able to step a motor up gradually, but drives can be programmed to ramp up the motor much more gradually and smoothly, and can operate the motor at less than full speed to decrease wear and tear. Variable speed drives can also run a motor in specialized patterns to further minimize mechanical and electrical stress. For example, an S-curve pattern can be applied to a conveyor application for smoother decel/accel control, which reduces the backlash that can occur when a conveyor is accelerating or decelerating.

    Problems Caused by Full-Voltage Starters

    At the instant of energization, the locked rotor (zero-speed) is about 600% of full-load running current This heavy current then drops off gradually as the load breaks loose, and the  motor comes up to speed, but causes unacceptable voltage sag on the power system, adversely affecting other loads. It can also cause shock damage and long-term excessive wear on the motor.  Using this starting method may force the utility to impose a limit on the size of motors you can use, since across-the-line starting causes problems upstream into the utility's system, creating problems for other customers. The switching surges of abruptly starting and stopping create stress on the motor insulation.