EMC

Testing Capabilities

SaltLake City 801. 366.4100 / 800. 433.4548   -    Denver 303. 574.9448    -    Boise 208. 573.1038    -    Portland 503. 616.4677
EAM Testing Capabilities

Just Some of The Many Capabilities of Electrical Asset Mgmt

Utility
- Basic maintenance
- Cable-ampacity study
- Coordination study
- Demand analysis
- Electrical distribution analysis
- Electrical disturbance analysis
- Electrical parameter analysis
- Ground-mat study
- Ground resistance survey
- Harmonics analysis
- Infrared testing
- Load-flow study
- Maintenance contracts
- Overpotential testing
- Power-factor testing
- Reliability study
- Repair
- Switching-transients study
- Training
- Verify correct installation

Switchgear
- Basic maintenance
- Breaker testing
- Cable-ampacity study
- Coordination study
- Current injection test
- Demand analysis
- Electrical distribution analysis
- Electrical disturbance analysis
- Electrical parameter analysis
- Ground-mat study
- Ground resistance survey
- Harmonics analysis
- Infrared testing
- Load-flow study
- Maintenance contracts
- Overpotential testing
- Power-factor testing
- Reliability study
- Repair
- Switchgear testing
- Switching-transients study
- Training
- Verify correct installation

Transformer
- Basic maintenance
- Demand analysis
- Harmonics analysis
- Infrared testing
- Insulation-resistance testing
- Maintenance contracts
- Overpotential testing
- Polarity testing
- Power-factor testing
- Ratio verification testing
- Reliability study
- Repair
- Training
- Turns-ratio testing
- Verify correct installation

Distribution Switchgear
- Basic maintenance
- Breaker testing
- Cable-ampacity study
- Coordination study
- Current injection test
- Demand analysis
- Electrical distribution analysis
- Electrical disturbance analysis
- Electrical parameter analysis
- Ground-mat study
- Ground resistance survey
- Harmonics analysis
- Infrared testing
- Maintenance contracts
- Reliability study
- Repair
- Short-circuit study
- Switchgear testing
- Switching-transients study
- Training
- Verify correct installation

Motor Control Center
- Basic maintenance
- Cable-ampacity study
- Coordination study
- Demand analysis
- Electrical distribution analysis
- Electrical disturbance analysis
- Electrical parameter analysis
- Electromagnetic field testing
- Ground-mat study
- Ground resistance survey
- Harmonics analysis
- Infrared testing
- Maintenance contracts
- Reliability study
- Repair
- Short-circuit study
- System function testing
- Training
- Verify correct installation

Variable Frequency Drive (VFD)
- Basic maintenance
- Capacitor on filler testing
- Contactor testing
- Cooling fan check
- Coordination study
- Demand analysis
- Electrical distribution analysis
- Electrical parameter analysis
- Harmonics analysis
- Infrared testing
- Inverter inspection
- Load testing
- Maintenance contracts
- Reactor testing
- Reliability study
- Repair
- Static check
- Training
- Verify correct installation
- Wave form testing

Panel board
- Basic maintenance
- Cable-ampacity study
- Coordination study
- Demand analysis
- Electrical distribution analysis
- Electrical disturbance analysis
- Harmonics analysis
- Infrared testing
- Maintenance contracts
- Reliability study
- Repair
- Short-circuit study
- Training
- Verify correct installation

Automatic Transfer Switch
- Basic maintenance
- Demand analysis
- Gen link
- Infrared testing
- Insulation-resistance testing
- Maintenance contracts
- Reliability study
- Repair
- Switching-transients study
- Training
- Verify correct installation

Emergency Switchboard
- Basic maintenance
- Breaker testing
- Cable-ampacity study
- Coordination study
- Current injection test
- Demand analysis
- Electrical distribution analysis
- Electrical disturbance analysis
- Electrical parameter analysis
- Ground-mat study
- Ground resistance survey
- Harmonics analysis
- Infrared testing
- Maintenance contracts
- Reliability study
- Repair
- Short-circuit study
- Switchgear testing
- Switching-transients study
- Training
- Verify correct installation

UPS
- Basic maintenance
- Cable-ampacity study
- Coordination study
- Demand analysis
- Electrical distribution analysis
- Electrical disturbance analysis
- Electrical paramter analysis
- Harmonics analysis
- Infrared testing
- Maintenance contracts
- Ohmmeter testing
- Overpotential testing
- Power-factor testing
- Reliability study
- Repair
- Short-circuit study
- Switching-transients study
- Training
- Verify correct installation

Standby Generator
- Basic maintenance
- Cable-ampacity study
- Coordination study
- Demand analysis
- Engine shut-down testing
- Gen link
- Ground-mat study
- Ground resistance survey
- Harmonics analysis
- Infrared testing
- Maintenance contracts
- Overpotential testing
- Phase-rotation testing
- Power-factor testing
- Relay testing
- Reliability study
- Repair
- Training
- Verify correct installation

Motors
- Basic maintenance
- Cable-ampacity study
- Coordination study
- Demand analysis
- Ground resistance survey
- Harmonics analysis
- Infrared testing
- Insulation-resistance testing
- Maintenance contracts
- Motor-field winding
- Motor-starting testing
- Overpotential testing
- Power-factor testing
- Reliability study
- Repair
- Stator resistance testing
- Training
- Verify correct installation
- Vibration analysis

  • About Electrical Asset Management
  • About Preventive Maintenance
  • About Power Quality
  • Industry Breakdown